Custom biosensors









Electronic Division
Biosensor and screen-printed electrode manufacturing
Topflight makes custom biosensors and screen-printed electrodes for electrochemical, analytical, medical and environmental applications: as an intermediate or finished product, from the conductive substrate to dedicated reagents and final packaging to the customer’s specifications.
Custom biosensors
Topflight custom biosensors can include a conductive substrate, reagents, plastic materials and final packaging, and are supplied as an intermediate or finished product according to the customer’s specifications.
We develop devices for electrochemical, analytical, medical and environmental applications.
Screen-printed electrodes
A screen-printed electrode (SPE) is a miniaturized electrochemical cell printed with conductive inks on a flexible or rigid substrate. The working electrode, the counter electrode and the reference electrode are usually printed on the same substrate.
The technology is precise, scalable and cost-effective, and is suitable for electrochemical analysis, medical devices, wearable technologies and environmental monitoring.
How an electrochemical biosensor works
An electrochemical biosensor converts a biological reaction into a measurable electrical signal. It is made of a receptor and a transducer and is designed to detect specific substances or parameters quickly and reliably.
Advantages: quick and easy application; freedom in graphics and size; flexible production, including made-to-order.
Manufacturing technologies
The process includes screen printing, reagent deposition, lamination, assembly and die-cutting. Machines with optical alignment ensure high precision and tight tolerances, for stable, uniform and reliable sensors.
Materials and electrochemical specifications
Materials: polyester, polycarbonate, graphite, Ag/AgCl, gold and UV-curable insulators. On request we integrate materials specified by the customer.
Measured performance. The electrochemical performance of our cells is documented in two test reports: CS-4.0 and AuS-4.0. Main data:
CS-4.0 cell
- Cyclic voltammetry (CV) in a ferro/ferricyanide probe: 5 mM K₃Fe(CN)₆ in 0.1 M KCl, pH 7; window −0.8 to +0.8 V; scan rate 0.01 to 1 V/s.
- Active area (Randles–Ševčík equation): 3.47(2) mm² in one test; 3.1(5) mm² in a second test after an ethanol wash.
- Repeatability (3 sets of 10 scans at 0.1 V/s): anodic peak current 32(1), 34.1(5) and 34.8(4) µA; cathodic −41(1), −41.7(6) and −42.2(6) µA.
- Dopamine by differential pulse voltammetry (DPV; 0.1 M PBS with 0.1 M KCl, pH 7): calibration line Ip [µA] = 0.01252(1) · C [µM] + 0.176(4), R² = 0.9999; limit of detection (LOD) 0.8 µM; limit of quantification (LOQ) 2.4 µM.
AuS-4.0 cell
- CV in the same probe, window −0.8 to +0.3 V; in tests 2–4 after a pretreatment of 10 cycles in 0.5 M H₂SO₄.
- Active area: 5.9(7) mm² and 7.4(9) mm² in two tests.
- Peak currents in test 3: anodic 65.0(2) µA, cathodic −59.7(2) µA.
The number in brackets is the uncertainty on the last digit: 3.1(5) means 3.1 ± 0.5. Values refer to the tests described in the reports.
Reagents, sectors and research and development
We deposit reagents supplied by the customer or developed with laboratories and research centers. Applications range from medical and diagnostic to environmental, food, scientific research, industry and wearable devices.
R&D support goes from the choice of materials to the prototype, with in-house laboratories and scientific collaborations.
Scientific publications
Topflight screen-printed electrodes have been used in research published in international open-access scientific journals. Topflight Italia S.p.A. (Vidigulfo, Pavia) is the supplier of the screen-printed cells used in these studies. The electrodes were modified with molecularly imprinted polymers (MIP) to detect irbesartan, phenoxy herbicides, atrazine, dopamine, ascorbic acid and gallic acid.
- Voltammetric Detection of Irbesartan by Molecularly Imprinted Polymer (MIP)-Modified Screen-Printed Electrodes
Zanoni C. et al. (2022). Chemosensors 10(12), 517. DOI 10.3390/chemosensors10120517 - Potentiometric MIP-Modified Screen-Printed Cell for Phenoxy Herbicides Detection
Zanoni C. et al. (2022). International Journal of Environmental Research and Public Health 19(24), 16488. DOI 10.3390/ijerph192416488 - Molecularly Imprinted Polypyrrole-Modified Screen-Printed Electrode for Dopamine Determination
Merli D. et al. (2024). Polymers 16(17), 2528. DOI 10.3390/polym16172528 - MIP-Based Screen-Printed Potentiometric Cell for Atrazine
Alberti G. et al. (2022). Chemosensors 10(8), 339. DOI 10.3390/chemosensors10080339 - MIP-Based Screen-Printed Electrode for Irbesartan Sensing
Rovida R. et al. Engineering Proceedings 31(1), 22 (ASEC 2022 proceedings). DOI 10.3390/ASEC2022-13836 - Ascorbic Acid Sensing by Molecularly Imprinted Electrosynthesized Polymer (e-MIP) on Screen-Printed Electrodes
Alberti G. et al. (2023). Chemosensors 11(6), 348. DOI 10.3390/chemosensors11060348 - A Screen-Printed Voltammetric Sensor Modified with Electropolymerized Molecularly Imprinted Polymer (eMIP) to Determine Gallic Acid in Non-Alcoholic and Alcoholic Beverages
Zanoni C. et al. (2024). Polymers 16(8), 1076. DOI 10.3390/polym16081076
Frequently asked questions
Frequently asked questions about biosensors
Answers to the questions we are asked most often by laboratories, researchers and purchasing departments.
What is an electrochemical biosensor?
It is a device that converts a biological reaction into a measurable electrical signal. It consists of a receptor and a transducer and is designed to detect specific substances or parameters quickly and reliably.
What are screen-printed electrodes?
They are electrodes made by screen printing on flexible or rigid substrates. They are precise, scalable and cost-effective, and are used for electrochemical analysis, medical devices, wearable technologies and environmental monitoring.
What materials do you use?
Polyester, polycarbonate, graphite, Ag/AgCl, gold and UV-curable insulators. On request, materials specified by the customer can be integrated.
Can you deposit customer-supplied reagents?
Yes: we deposit reagents supplied by the customer or developed together with laboratories and research centers, and we can supply the finished biosensor with custom packaging.
Do you also make small quantities or prototypes?
Yes: flexible production allows us to make prototypes and small runs on request, as well as larger volumes.
What is the difference between a screen-printed electrode and a biosensor?
A screen-printed electrode is the electrical transducer: electrodes printed on a flexible or rigid substrate. It becomes a biosensor when a recognition element, such as an enzyme, an antibody or a molecularly imprinted polymer, is deposited on its surface. Topflight supplies the intermediate product or the finished biosensor, with reagents supplied by the customer or developed with laboratories and research centers.
What electrochemical performance do your cells have?
In which scientific studies have your electrodes been used?
In seven studies published between 2022 and 2024 in Chemosensors, Polymers, the International Journal of Environmental Research and Public Health and Engineering Proceedings. The electrodes were modified with molecularly imprinted polymers to detect irbesartan, herbicides, atrazine, dopamine, ascorbic acid and gallic acid. The list with DOIs is in the “Scientific publications” section of this page.
Which measurement techniques are your cells used with?
In the test reports and the published studies, the cells were used with cyclic voltammetry, differential pulse voltammetry and potentiometric measurements.
How do I request a quote?
Send us your specifications, materials, reagents and quantities through the contact page: our technical office will reply with a proposal.
Electronic Division
Membrane switches
Need a thin, sealed push-button interface? Discover Topflight membrane switches: custom-made and UL certified.
get in touch
Contacts
- Operational Headquarters: Via C. Colombo 5, 27018 Vidigulfo (PV) - Italy
- Registered Office: Via Sebastiano Veniero 8, 20148 Milan - Italy
- topflight@topflight.it
- +39 0382 69108
- +39 0382 1855551
To receive more information, please fill out the form below. Our team will get back to you as soon as possible.